The frame is the last look at structure, and in this corridor it is where the engineering gets checked against what was actually built.

  • Once frame and trusses are up and the roof is on, before sarking
  • 1 to 2 hours on site
  • Report within 24 hours
Price a Rockbank inspectionA minute to complete, nothing committed.

Fully licensed & accredited

Stage3 of 7
When to bookOnce frame and trusses are up and the roof is on, before sarking
Time on site1 to 2 hours on site
Inspected againstAS 1684 (timber framing), AS 4100 or NASH for steel frames, the engineer's bracing and tie-down plan, NCC Part 3.4

What is included in a Rockbank frame inspection

  • Stud, plate, lintel and beam sizes against AS 1684 and the engineer's drawings
  • Wall straightness and plumb, top plate level
  • Floor level across the slab
  • Bracing type, position and fixing against the bracing plan
  • Tie-downs from roof to wall and wall to slab
  • Triple grips, straps and bolt fixings
  • Jack studs, lintels and trimmers over every opening
  • Window sill trimmers for wide openings
  • Roof truss spacing, fixing and girder connections
  • Valley boards, ceiling battens and roof bracing
  • Window and door openings against the plans
  • Wet area framing, noggings and service penetrations
  • Damaged, split, notched or over-drilled members
  • Termite collars and slab penetrations still visible
Why it matters here

Frame inspections on Rockbank builds

Girder trusses left unsupported at their bearing, strap bracing fitted but never tensioned, and top plate anchors the engineer prescribed and nobody installed. All three look finished and none of them work.

What we find at this stage in Rockbank

  • Girder truss unsupported at its bearing point
  • Metal strap bracing installed but not tensioned
  • Top plate to stud anchors missing where prescribed
  • Top plates not built to the prescribed size
  • Bracing shown on the engineering not installed
  • Roof truss sections damaged
Bracing shown on the engineering plans not installed, Rockbank
Bracing shown on the engineering plans not installed
Sections of roof truss damaged, Rockbank
Sections of roof truss damaged
Sample findings

Sample defects found during our frame inspections in Rockbank

Annotated findings from Frame inspections on Rockbank builds. Client addresses withheld.

Girder truss unsupported at its bearing point, recorded during a frame inspection in Melton, 7 km from Rockbank
Girder truss unsupported at its bearing point
Metal strap bracing installed but not tensioned, recorded during a frame inspection in Fraser Rise, 4 km from Rockbank
Metal strap bracing installed but not tensioned
Top plate to stud anchors missing where prescribed, recorded during a frame inspection in Melton, 7 km from Rockbank
Top plate to stud anchors missing where prescribed
Top plates not built to the size the engineer prescribed, recorded during a frame inspection in Melton, 7 km from Rockbank
Top plates not built to the size the engineer prescribed

The other stages of a Rockbank build

  1. Bored piers inspection in Rockbank1Bored piersAfter boring and cage placement, before concrete
  2. Slab pre-pour inspection in Rockbank2Slab pre-pourThe day before the pour, with steel and formwork open
  3. Lock-up (pre-plaster) inspection in Rockbank4Lock-up (pre-plaster)After roof, cladding and external doors, before plaster
  4. Fixing inspection in Rockbank5FixingAfter mouldings, doors and joinery, before painting
  5. Waterproofing inspection in Rockbank6WaterproofingAfter the membrane is applied and cured, before tiling
  6. Pre-handover (PCI) inspection in Rockbank7Pre-handover (PCI)About a week before practical completion

All construction stage inspections in Rockbank →

Guides

Construction stage guides for Rockbank

All guides →

Book a frame inspection in Rockbank

Instant online pricing, or talk to the booking team on 1300 471 805.

FAQ

Frame inspections in Rockbank: common questions

What is a girder truss?

The main supporting truss that carries other trusses. Unsupported at its bearing point it is carrying load it was not designed to carry that way, which makes it a structural item.

Why does tensioning matter?

Strap bracing resists load only when tensioned. Fitted loose it looks installed and contributes nothing to the frame.

How do anchors get missed?

The engineering nominates them at specific points. If nobody compares the frame to the drawing, an omission passes and gets lined over.

Do you check trusses?

We check support, fixing, bracing and damage. Design certification for trusses comes from whoever fabricated them.

Which standards?

AS 1684 for framing with AS 4055 for wind classification, alongside your engineering.

Visible later?

Not without opening the wall or the ceiling.